中文 |  Inquiry |  TEL:0086-372-3389658   Anyang Forging Press Group

Please select anyang branch company to know more Anyang products.

Email: hydr-hammer@chinesehammers.com

Forging Hammers

LOCATION:HOME >> Repair and maintenance

 

Fully hydraulic hammer failure removal

PROBLEM 

REASON 

METHOD 

Handle is in return position, tup can’t go up 

1.air cylinder and accumulator pressure is not normal.
2.main valve core action distance is wrong.
3.tup and guide are blocked
4.Quick release valve is blocked 

 

1.Ajust inflated pressure by technical parameter.
2.Ajust operation system.
3.Find the reason and remove.
4.Dismantle and repair 

Tup can’t go down

Main valve core action distance is wrong.

Find the reason and remove

Oil temperature is go up quickly

 

1.Electro unloading valve is not normal.
2.Cooling water is no use( Electric cooler is not good)

1.Adjust electro unloading vavle 
2.Check water cooler or electric cooler.

Tup hitting is weak

1.Main valve core action is wrong,
2.Quick release valve strain
3.Air cylinder pressure is not enough. 

1.Check valve core action distance
2.dismantle and repair
3. Adjust pressure.

Link cylinder girder have a voice of release oil, tup can’t be lift.

Safety valve pressure small

Adjust safety valve to normal 

 

16mpa pressure gauge reduced

1.Pressure gauge damaged
2.Pipeline gas leakage
3.hammer rod piston upper sealing damaged

1.Change pressure gauge
2.repire pipeline
3.Change sealing

16mpa pressure gauge rise

1.Air pressure in air cylinder enter oil
2.Pressure gauge damaged
3.Cushion cylinder seals damaged
4.Oil temperature rise

1.Open valve and release oil
2.Change pressure gauge
3.Change seals

25mpa pressure gauge reduced

1.pressure gauge damaged
2.pipeline gas leakage
3.accumulator piston upper seals damaged

1.Change pressure gauge
2.repair pipeline
3.Change seals

25mpa pressure gauge rised

1.oil enter gas cylinder.
2.pressure gauge damaged
3.oil temperature rise

1.Open valve and release oil
2.Change pressure gauge